Integrated Intelligent "Load Cutout" Function

Exclusive Features:

  • Class of Accuracy : 0.25%

  • Large backlit display

  • Effective True Value Measurements of all main electrical parameters

  • Active and reactive energy readings always shown on display 

  • Partial energy meter for checking consumption in individual operating cycles

  • Voltage and current THD (Total Harmonic Distortion Factor) measurement

  • FAST data acquisition ensuring high -precision measurements

  • Automatic configuration of CT side, which means easy installation

  • CT setting for controlling the cogeneration 

  • 2 outpouts that may be selected for pulses or alarms

  • RS-485 for remote connection and data transmission 

  • 2 available protocols : DCT and MODBUS-RTU 

  • Programmable use of map to facilitate use of MODBUS

  • Automatic network recognition 

  • Easy set up with examples to guide user

  • Page first selection on display

  • Safety password on set up and on energy measurements

Technological Innovation Means Saving on Electric Measurements

The new and economical SMART Pił analyzer futher broadens the consolidated family of MACH 30 (three- phase and SMART  panel board-type analyzing instruments. It is the pr0duct of strategy aimed at consolidating the brand's presence in the field of measuring instruments through a line of highly technological products and systems that meet Company's traditional needs to economize and optimize electricity consumption. 

The SMART Pił panel board-type analyzers have been designed and manufactured to be used in low and medium voltage electricity distribution panel boards. The SMART Pił measures and computes the main electric quantities specified in the table on page 36. The computing values of average powers may be set for times ranging from 1 to 60 minutes .

The precision is about 0,25% 25 quantities may be viewed in a series of pages on a liquid crystal display on front. Finally an extremely important plus is that an RS-485 serial port is available in each SMART Pił so that measurements can be sent to a data recording system as described in the "ENERGY MANAGEMENTS " section.

Load Control Pulse Outputs
Lo SMART Pił, nella versione 2p , ha due rele di uscita che possono essere configurati dall'utente in tre diverse modalita come di seguito riportato

The 2p version of SMART Pił has two output relays that can be configured in three different modes as follows

 

 


"Load control" mode

The SMART Pił analyzer incorporates a "LOAD CUTOUT" function for controlling power peaks in order to avoid costly surcharges.

A sophisticated predictive algorithm monitors the power consumption trend. Whenever it is dermined that the maximum allowed value may be exceeded, an output relay is activated and load is cut out. 

As result, before the power peak arises , non-priority loads can be cut out or the user warned.

"Alarm Threshold" mode

The SMART Pił analyzer incorporates an "ALARM THRESHOLD" function for keepeng the maximum values of the main electric parameters under control.

If a parameter exceeds a programmed value, a relay to which the threshold has been assigned is activated. 

This function enables the user to control peak values of voltage, current etc.

"Pulse Emission mode"

The SMART Pił analyzer incorporates a "PULSE EMISSION" function for transferring data on the consumption of Active Power (kW) and Reactive Power (k VAr) to a PLC.

Why The Load Cutout Function?

SMART Pił represents a technological innovation because besides being a highly precise measuring instrument it can signal when loads exceed a set level and disconnect users that have been identified in advance by the Company in order to avoid excessive consumption and reduce the power demands make of the electric company. Let's not for- get the power is paid not only on the basis of a fixed charge but also according to demand , which means high costs per KW,

The diagram illustrates the concept clearly, When the instrument detects the the power limit is about to be exceeded, it signals the necessity of disconnecting loads with an internal relay, which in turn activates the controls for immediately cutting out the selected load. As soon as the demand has been brought down to normal levels, the load can be normally reconnected. Cooling units, compresors and machines that are less important for production Remember that savings does not means less work, but rather using resources efficiently so as to minimize energy costs and thereby gain a competitive edge.

The New Approach To Production AIMS At Maximizing Competitiveness

To achieve this result it is not enough to buy energy at the most convenient price or shut down equipment. Today, being competitive means controlling consumption and organizing production taking into account all the parameters that may impact the cost of the final product. Businesses and workers have to learn how to organize their production cycles and examine every possible and feasible solution.

Those who formulate work plans must make it clear that turning on equipment a minute too soon or minute too late may result it unacceptable cost, Costs. Costs that a Company must pay. But without an instrument it is impossible to detect excess loads; SMART Piu cna monitor and intervene to optimize energy consumption. SMART Piu is the right answer to the problem.

Measurement Pages

Only 4 pages in which to view three-phase parameters. Furthermore, the voltages, currents and power factor are available for each line, as well as the average and max. average power. Active and reactive energy are stored in a non-volatile memory. 

The active and reactive energies of the tree-phase system or, if selected, of the individual phases, always appear at the bottom of the display.

Other configuration and setting pages are available together with a guided menu for easy configuration.

High Resolution Display And Backlit Display
80x30 MM, 160 segments, TN technology. Two measurements parameters displayed at the same time. Active and reactive energy metes always displayed.

Immediate access to the menu.

It is also possible to scroll pages up and down in the SETUP menu for an easier configuration.

Special Functions

"Password" Function
The configuration of the SMART Pił, including the energy meters - is protected by a safely password.

"Partial Energy Meter" Function
You can rely on a partial energy meter to measure consumption in preset periods of time. Resetting the partial meter will have no effect on the overall measurements.

"Simplified Configuration" Function
Configuring the SMART Pił is easy: codes for the three phase, single-phase and balanced three-phase configurations are already entered in the setup menu.

"Firmware Update" Function
The FW version is indicated in a specific configuration page. In the SMART Pił, the FW is stored in a "Flash" memory and can be edited in case of need, directly in field.

Easy Reading And Configuration
Only two keys:
Page + select menu for configuration

Page
       key to change page

Select
      key for configuration

CT and VT may be programmed from 1 to 1,000 and from 1 to 500.
Parameters for the RS-485 Serial Port Configurable.
Time for calculating average power may range from 1 to 60 minutes.

Technical Specifications
Accuracy:
Voltages 
Currents 
Active power 
Power Factor   
Frequency 

: ±0.25%±0,3% Full Scale
: ±0.25%±0,3% Full Scale
: ±0.5% (cosφ=0.3Ind.to cosφ =-0.3cap)
: ±0.5%(cosφ=0.3Ind.to cosφ =-0.3cap)
: ±0.2%(40÷500Hz)
Range:
Voltages 
Currents 
A/D conversion 



: from 5 Vr.m.s to 500 Vr.m.s. with VT up to 50000/100
: 5A version: from 50Ar.m.s to 5Ar.m.s. with CT up to 5000/5
: 10 bit

Power supply:
AC model
AC model
Power  
Temperature 
RH 
Weight 
Display  
keyboard 
RS485 Serial output 
... 
Pulse output 
Protection rating  

: 230/115Vac +5%-15% from45 to65Hz
: 240/120Vac +5%-15% from45 to65Hz
: < 6VA
: from 0°C to 50°C
: 90% without condensation at 40°C
: 0,46kg
: LCD 30x80mm.character height: 1cm backlit (only smart 96)
: 2-key matrix
: 9600 bits/seconds
: MODBUS-RTU, Ducati-BUS
: (only 2p model)
: Instrument IP20-front panel IP40 

Technological Innovation
SMART Pił is conceived and manufactured and manufactured according to the most advanced technologies in order to grant a high reliability. The accuracy in measurement is 0.25% as to Voltage and Current, and 0.50% as to Active Power.

Wirings Smart 96

A three-phase connection with direct voltmeter input (LV) and an amperometric input through CT with 5A secondary winding.

Dimensions

Smart Applications

 